Type at least two characters. Arrow keys to browse, Enter to open, Escape to close.

    Expertise 04 · Extra-low voltage (ELV) and security

    Coordinated communication, security and safety systems.

    CCTV, access control, intercom, public address, telephony and fire safety: we integrate the systems specified for your project, respecting the function of each one and defining their interfaces.

    Area 04

    • Security
    • Communications
    • Fire safety

    Main interfaces

    IT and cybersecurity · Electrical power · BMS and GRMS · Hospitality technology

    Challenges

    Separate systems that must work together.

    1. Each system in its place

      Security, communications and fire safety meet different objectives and requirements. We handle them separately before organising how they interact.

    2. Interfaces defined and tested

      Door release, public address muting, alarm reporting: each planned interlock is described, validated with the parties involved, then tested.

    3. Everyday operation

      Control stations, access rights and procedures must remain clear for the teams who will use them after handover.

    Scope

    Three families of systems, handled according to their function.

    The systems delivered depend on the assignment. Their functions and performance levels are set by each project’s specification.

    • Security

      • CCTV
      • Access control for public and technical areas
      • Electronic locks and hotel access control
      • Perimeter protection, depending on the project
      • Control stations and operator rights
    • Communications

      • Telephony
      • Intercom and door entry
      • Public address, background music and message broadcasting
      • Nurse call, in healthcare facilities
    • Fire safety

      • Fire safety systems, depending on scope
      • Fire detection
      • Safety actions and interlocks defined for the project

      The fire safety system keeps its own functions and controls. The BMS can receive information from it without replacing it.

    Scope conditions

    • Functions, performance levels and interlocks are defined in each project’s specification.
    • Applicable regulatory requirements and operator standards are identified project by project; we do not claim general compliance.

    Interfaces

    Exchanges described in a matrix, then tested.

    Each interface has a sender, a receiver, an expected behaviour and an associated test.

    How we work

    System by system, then interface by interface.

    1. Needs and constraints

      Areas, people flows, operating hours and project requirements.

    2. Layouts and architecture

      Device positioning, system architecture and interface matrix.

    3. Installation and configuration

      Installation, connections and configuration, coordinated with the other packages.

    4. Functional testing

      System-by-system tests, then interface tests with the parties involved.

    5. Handover

      Operator training and delivery of operating documentation.

    Deliverables

    Example deliverables

    Deliverables are defined in each proposal, according to the assignment.

    • Device layout drawings
    • Block and wiring diagrams
    • Interface matrix
    • Functional test reports
    • Operating documentation

    Sectors

    Different needs and different audiences.

    Frequently asked questions

    ELV systems: your questions.

    Can fire safety be controlled by the BMS?

    No. The fire safety system keeps its own functions and controls. The BMS can receive certain statuses or alarms, as defined and validated in the project.

    Can you take over an existing CCTV installation?

    We first study what is in place: cameras, recorders, network and how the system is used. Depending on compatibility and condition, we propose to keep, extend or replace the equipment.

    Who tests the interlocks?

    Interface tests are prepared with all the parties involved. We write or complete the test plan for our scope and take part in the joint tests planned for the project.

    Do you train the operating teams?

    Training is provided according to the assignment: use of control stations, rights management and basic procedures, with the corresponding documentation.

    First conversation

    Let’s look at your security and communication systems.

    Tell us about your project: we will identify the systems and interfaces to address.

    • Type of building and areas concerned
    • Existing systems
    • Project phase
    • Known requirements: specification, operator standard

    Discuss your project

    Discuss your ELV systems

    or contact us directly:

    Discuss your project